Housing: |
Self-extinguishing plastic, UL 94 V0 |
|
| |
Dimensions: |
70x85 mm (4 DIN modules) – depth 61 mm |
|
| |
Weight: |
280 g approx. |
|
| |
Connections: |
2,5 mm 2 screw terminal block |
|
| |
Mounting: |
On OMEGA DIN rail |
|
| |
Front panel protection: |
IP 40 (front) |
|
| |
Power supply: |
24, 110, 230 VAC +/-10% |
|
| |
AC Frequency: |
50 / 60 Hz |
|
| |
Power consumption: |
3 VA approx. |
|
| |
Thermistors: |
2 x PTC KTY 81-121 – 990 Ω at 25°C |
|
| |
|
2 x NTC 103 AT-2 – 10 KΩ at 25°C |
|
| |
Digital input: |
1 programmable auxiliary input for free-voltage contacts |
|
| |
Relay outputs: |
Up to 4 Outputs :
1 relay for compressor
- 16A-AC1, 6A-AC3 / 250VAC; 1HP 250VAC, 1/2HP 125 VAC |
|
| |
|
1 relay for defroster, 1 relay for fans , (optional: 1 auxiliary
relay)
- 8A-AC1, 3A-AC3 / 250VAC; 1/2HP 250VAC, 1/3HP 125VAC |
|
| |
Control: |
ON/OFF |
|
| |
Overall accuracy: |
+/-0.5% fs |
|
| |
Sampling rate: |
2 samples per second |
|
| |
Display resolution: |
1° in all the range or 0,1° in the range of –19,9…19,9 |
|
| |
Measurement range: |
PTC: -50 … 150°C / -58 … 199°F
NTC: -50 … 50°C / - 58 … 122°F |
|
| |
Defrost control: |
At time intervals or at programmed real times (REAL TIME CLOCK
DEFROSTING), with electric heating or by reverse cycle-hot gas |
|
| |
Endurance of the internal clock without supply: |
7 years approx. by means of internal battery |
|
| |
Unit of measurement: |
°C - °F, programmable |
|
| |
Acoustic alarm: |
Internal Buzzer |
|
| |
Operating temperature: |
0…55°C |
|
| |
Operating humidity: |
30…95 RH% without condensation |
|
| |
Goedkeuring: |
CE, RoHS en WEEE |
|
| |
| |
Leveringsomvang: |
|
|
| |
|
l |
IR58 Thermost -50/150 230V 3r 2xPTC RAIL |
|
l |
Montagebeugel |
|
l |
Engelse Gebruiksaanwijzing |
|
|
|