Opties |
|
|
|
|
MB40 Capaciteit & UTP en STP bedradingstester |
| |
|
|
|
 |
| |
|
|
|
|
r |
Hub blink mode sends link pulses
to network switch to blink port LED. |
|
r |
Measures cable length using
patented cable capacitance method. |
|
r |
Displays single-ended test
results in wiremap format for opens, shorts, and
split pairs. |
|
r |
Tests and displays in wiremap
format shorts, opens, miswires, reversals, and
split pairs with remotes. |
|
r |
Two-line, 16-character, back-lit,
full alphanumeric LCD with icon flags. |
|
r |
Auto-off and timed backlight in
any mode for low power consumption and long
battery life. |
|
r |
Application:
|
|
- |
Installation, troubleshooting, and
maintenance on telco, network, or coax cable.
|
|
- |
Identify switch port LED where
network cable is terminated.
|
|
- |
Measure cable length.
|
|
- |
Determine wiring condition.
|
|
- |
Identify up to 20 telco, network, or
coax cable runs at a time.
|
|
- |
Find and fix position of exposed or
hidden cable.
|
|
|
|
|
|
| |
|
The MB40 provides telecom,
datacom, and cable installers and technicians
with cable test, length measurement, and hub
blink functions in one unit. The easy-to-use
MB40 requires one-button operation to initiate
telco, network, and coax modes for diagnostic
tests and results. The main unit includes
built-in RJ12 and RJ45 jacks for testing
six-wire and eight-wire twisted pair and
F-connector for testing coax. An integrated
remote bay houses a detachable test remote with
built-in jacks for testing twisted pair cable
terminated with RJ12 or RJ45 connectors. The
MB40 performs detailed analysis to detect
miswire, no connection, short, high-resistance
fault, and split pair conditions when used with
remote identifiers. It also tests and reports on
shorts, opens, and split pairs conducted without
a remote. The MAP ID function identifies
multiple cables by displaying ID numbers of
map-only remotes. The MB40 measures cable length
and displays PASS icon for correctly wired
T568A/B and six-pin cable. Tone generator mode
sends any of four user-selectable tones on all
pin and pair combinations. |
|
| |
|
|
|
|
Specificaties |
|
|
|
|
| |
|
|
|
|
Cable types: |
Shielded or unshielded,
CAT6, CAT5E, CAT5, CAT4, CAT3, and Coax |
|
Minimum cable length for
testing for split pairs: |
0.91 m |
|
Minimum cable length for
PRETEST: |
1.22 m |
|
Length measurement
range: |
(CAT5/6): 0 to 610
meters (0 to 2000 feet) |
| |
Coax cable: 100Ω maximum
DC resistance, center conductor plus shield |
|
Battery life: |
Battery life (based on a
typical 9 V Alkaline battery) is for the full
capacity of the battery used continuously in one of
the following modes (batteries not included) |
| |
Standby: 2.5 yrs |
| |
Cable testing: 80 hrs
(with backlight off) |
|
Operating temperature: |
0 to 50°C |
|
Storage temperature: |
- 10 to 60°C |
|
Humidity: |
10% to 90%,
non-condensing |
|
Size - (Excluding
F-connector): |
3.3 x 6.7 x 15.7 cm |
|
- (Including F-connector): |
3.3 x 6.7 x 16.8 cm |
|
Weight: |
235.3 g. with battery
and remote |
| Goedkeuring: |
CE, RoHS en WEEE |
| |
|
|
|
|
Leveringsomvang |
| |
|
|
|
| l |
MB40
Capaciteit & UTP en STP bedradingstester |
| l |
IC05 Werkplekadapters |
| l |
KA04 2 krokodilbek naar 1 RJ45 |
|
| l |
KA45
Aansluitkabel RJ45-RJ45 shielded (2 stuks) |
| l |
ABQ2 Tas
MB40 |
| l |
Gebruiksaanwijzing |
|
|
Opties |
|
|
|
 |
| |
|
|
|