KF10
TDR en Weerstand kabellengtemeter |
| |
|
|
|
 |
| |
|
|
|
|
r |
TDR mode. |
|
r |
RFL mode. |
|
r |
Open mode. |
|
r |
Capacitance
measurement. |
|
r |
DC Voltage
measurement. |
|
r |
Resistance
measurement. |
|
r |
Easy to use,
lightweight and compact. |
|
r |
6.4" TFT color
LCD display. |
|
r |
RS-232C upload
port. |
|
r |
LCD indicator for
battery time. |
|
r |
Selectable
auto-off time. |
|
r |
Waveform trace
and diagnosis. |
|
r |
Rugged and
waterproof packing. |
|
r |
Optional spare
battery for doubling operating time. |
|
r |
PC software for
further analyzing, reporting and printing. |
|
r |
Metallic cable test
instrument: |
|
- |
MTDR
(Metallic Time-Domain Reflectometer).
|
|
- |
RFL
(Resistance Fault Locator).
|
|
- |
Open
Mode.
|
|
- |
- Measuring DC
voltage & resistance & capacitance.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
The KF10 is an excellent and highly accurate
portable measuring instrument to check problem
and distance to events on cable using three
testing methods: Metallic Time-Domain
Reflectometer(MTDR), Resistance Fault
Locator(RFL) and Open mode. It also provides
additional three functions, found in DMMs
(Digital Multi-Meters): DC voltage measurement,
resistance measurement and capacitance
measurement. The MTDR shows the continuity of
characteristic impedance along the cable under
test applying electrical pulses, which is ideal
for checking faults (such as complete open &
short, partial open & short, loose connection,
broken lines, loading coil etc.) on any cables
which consist of at least two metallic
conductors (such as telephone lines, power
lines, UTP networks, CATV or CCTV, lines etc.).
The RFL figures out the total length and
distance to the insulation resistance reduction
point on cables with three metallic conductors.
It calculates the distance and insulation
resistance with high accuracy. The Open mode
calculates the total length or distance to an
open circuit of extremely long cables up to
100km. It measures the total capacitance of the
cable under test and converts it to distance
based on the information about capacitance per
unit length of the cable. The KF10 performs all
the measurement process automatically and
displays the results in the graphic and tabular
forms through a color graphic TFT LCD screen
with 640x480 pixel resolution. The instrument is
designed to make the user determine easily the
conditions of the cable being measured. The KF10
is an excellent instrument for the cable
installation, maintenance, repair after fault
finding regardless of the cable installation
environment. |
|
| |
|
|
|
|
Specificaties |
|
|
|
|
| |
|
|
|
| MTDR
Mode |
|
|
Measurement range: |
3.2m ~ 20,000m for Coax
(Maximum testable cable length will vary with pulse
width and cable type) |
|
Maximum display resolution: |
10cm (variable up to 50m) |
|
Accuracy: |
0.1% +/-0.1m of reading for Coax
(Accuracy will vary with VOP of cable being tested) |
|
Test mode: |
L1, L1&M, L1-M, M |
|
Pulse width: |
5ns, 15ns, 45ns, 100ns, 200ns, 500ns,
1µ, 2µ, 5µ, 10µ |
|
Maximum storage capacity: |
100 waveforms |
|
Output impedance: |
Automatic output impedance control of
25, 50, 75, 100, 125, 150Ω |
|
Input bandwidth: |
300MHz |
|
Effective sampling rate: |
1GS/s |
|
Gain: |
0 to 66dB or better, maximum
sensitivity 1mV (full scale) |
|
Screen update rate: |
Maximum 3 times per second |
|
VOP (PVF): |
Variable from 30.0 to 99.9% (in 0.1%
step) |
| |
V : 90 to 300m/µ |
| |
V/2 : 45 to 150m/µ |
| |
|
| RFL Mode |
|
|
Maximum loop resistance: |
10Ω |
|
Loop resistance resolution: |
1Ω |
|
Maximum insulation resistance: |
20MΩ |
|
Insulation resistance resolution: |
10KΩ |
|
Insulation resistance accuracy: |
5% |
|
Distance accuracy: |
1% |
|
Distance resolution: |
1m |
| |
|
Open
Mode
(Capacitance Measurement) |
|
|
Maximum capacitance: |
20µF |
|
Accuracy: |
Range Accuracy |
|
|
up to
10nF: +/-3%
+/-100pF |
|
|
up to
1µF: +/-5% |
|
|
up to
20µF: +/-10% |
|
Distance resolution: |
1m |
| |
|
|
Voltage Measurement |
|
|
Current type: |
DC |
|
Maximum voltage: |
300V DC |
|
Accuracy: |
Range Accuracy |
|
|
up to
10V: +/-1%
+/- 0.5V |
|
|
up to
50V: +/-2% |
|
|
up to
300V: +/-3% |
| |
|
|
Resistance
Measurement |
|
|
Maximum resistance: |
100MΩ |
|
Accuracy: |
Range Accuracy |
|
|
up to 10kΩ: +/-1%+/- 5Ω |
|
|
up to 100kΩ: +/-1% |
|
|
up to 1MΩ: +/-3% |
|
|
up to 10MΩ: +/-5% |
|
|
up to 100MΩ: +/-5% |
| |
|
| General
Specifications: |
|
|
Display type: |
6.4" Color TFT LCD |
|
Internal memory: |
2MB |
|
Communication port: |
RS-232C compatible (1 start bit, 8
data bits, 1 stop bit, no parity and 38,400 baud
rate) |
| |
|
| |
|
| |
|
|
Storage temperature: |
-20°C ~ 70°C |
|
Operating
temperature: |
-10°C
~ 50°C |
|
Relative humidity: |
<95% |
|
Power supply: |
7.6V Li-ion
chargeable battery pack 8,800mAh / AC adapter |
|
Battery life: |
7 hours (extendable
up to 14 hours by using optional spare battery) |
|
Recharging time: |
7 hours |
|
Dimensions: |
267mm. x 247mm. x
127mm. |
|
Weight: |
2.7kg: |
| Goedkeuring: |
CE, RoHS en WEEE |
| |
|
|
|
|
Leveringsomvang |
| |
|
|
|
| l |
KF10
TDR en Weerstand
kabellengtemeter |
| l |
Gebruiksaanwijzing |
|
|
| |
|
|
|
 |
| |
|
|
|