  ABD2 Coax telecomgenerator  
       
 
       
r Tone and trace coax cable through splitters, wire shorts, and terminated cable to active components.
r Built-in F-connector for coax cable.
r Three tone outputs.
r POTS line simulator.
r Status indicators for off-hook and shorts.
r Constant output in all modes for the life of the battery.
r Auto-off in any mode.
r Applications:
-
Trace and troubleshoot wires in a home, business, or MDU complex.
-
Tone trace for triple-play installations, home theater, security, multi-room audio, satellite, and phone systems.
-
Locate wires lost in a wall.
-
Trace coax runs in a daisy chain, through splitters, or in shorted cables.
-
Check continuity of a circuit.
The ABD2 is optimized to tone on coaxial cable systems as well as for phone and data cabling. The ABD2 includes a high-power tone generator mode that enables tracing through ungrounded splitters or to equipment as well as tracing terminated or shorted coax cable. Probe mode is used for conventional tone tracing. The low-power tone generator mode supplies tone voltage and current comparable to common tone generators. The POTS simulator mode supports line voltage, line current, and dial tone functions with a talk battery performance that performs better than common tone generators.
Datacom contractors, telco installation and maintenance technicians, enterprise technicians, and cable installers and contractors alike value the tone strength, ability to tone and trace through splitters, multiple interfaces (phone, data, and coax), and generous talk battery capability of Tonax.
       
Specificaties
       
POTS simulator: On-hook voltage: 20 V DC nominal
  Off-hook current (standard 430Ωload): 21 mA nominal
  Dial tone (into 600Ω): –21 dBm
Output terminals withstanding voltage: Tone modes 250 V peak AC or DC
  POTS simulator 25 V peak AC or DC
  POTS line, protection device will operate
Tone generator (Constant output from new battery to 5.4 V): Tone frequencies (±1%)
- Dual 977 and 814 Hz
- Single 977 Hz
High power: Probe mode
- Tone voltage, typical (open circuit) 20 V p-p
- Tone power, typical (into 600Ω) 18 dBM
  Coil mode
- Tone current, typical (into 75Ω) 400 mA p-p
- Tone power, typical (into 75Ω) 280 mW
Low power: Probe mode
- Tone voltage, typical (open circuit) 5V p-p
- Tone power, typical (into 600Ω) 6 dBm
Power requirements: 1 pc. 9V alkaline battery
Battery life Alkaline, 540 mA-hr):  
- Times for exclusive use in (typical) Standby mode: 2 yrs
  POTS simulator, on hook 40 hrs
  POTS simulator, off hook 8 hrs
  Tone mode, Probe mode 27 hrs
Tone mode, Coil mode 13 hrs
Physical Dimensions: 11.4 x 4.4 x 3.3 cm
Weight: 142 gm. with battery
Goedkeuring: CE, RoHS en WEEE
       
Leveringsomvang
       
l ABD2 Coax telecomgenerator
l ABA7 Veiligheids aarde pen naar krokodilbek kabel 3 meter
l KA21 Adapter F afgeschermd
l Gebruiksaanwijzing